TM 10-3510-220-24
2-37.
WATER HEATER ELECTRIC CONTROL ASSEMBLY (CONT)
REPAIR (Cont)
(5) Remove two nuts (9) and two lockwashers (8) and lift ignition transformer up to clear
studs (7) and pull wires (3) out of conduit.
b. Install new ignition transformer (5) as follows:
(1) Feed two wires (3) through conduit (4).
(2) Set ignition transformer (5) in place on studs (7) and secure with two lockwashers (8) and
two nuts (9).
2-119