TM 10-3510-220-24
3-19. WATER HEATER ELECTRIC CONTROL ASSEMBLY (CONT)
DISASSEMBLY
1.
Remove receptacle (4) from circuit box (3).
a.
b.
c.
Remove four screws (10) cover plate (11) and gasket (14 ) with receptacle (4).
Tag and disconnect five wires (13) connected to the rear of receptacle (4).
Remove two screws (12) under the receptacle cap and separate receptacle (4) from cover
plate(11).
3-88