TM 10--3510--221--100023 00--1/2 blankAUXILIARY EQUIPMENT TROUBLESHOOTING0023 00OVERHEAD LIGHT DOES NOT TURN ON1. Check electrical connection at outlet box.Is light cable connected?YES Go to step 2.NO Properly connect cable. Return to normal operation.2. Check RESET button on GFI receptacle.Is button tripped?YES Press RESET button. Go to step 6.NO Go to step 3.WARNING208 VAC electrical power is present in main control enclosure. Use extreme caution when workinginside. Never place hands or tools on exposed wire connections. Death on contact may result if per-sonnel fail to observe this safety precaution.3. Open door on main control enclosure.4. Observe position of circuit breaker CB8 (WP 0008 00, Figure 1,13).Is circuit breaker ON?YES Go to step 7.NO Go to step 5.5. Position circuit breaker to ON then close and secure door.6. Check overhead light.Is lights on?YES Return to normal operation.NO Notify maintenance.7. Check lamp in overhead light.Is lamp burnt out?YES Replace lamp. Return to normal operation.NO Notify maintenance.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business