TM 10--3510--221--10
0002 00--10
LAUNDRY ADVANCED SYSTEM
EQUIPMENT DESCRIPTION AND DATA -- Continued
0002 00
HEATING SYSTEM
An oil--fired heater is used to generate heat needed to boil water in the still and to heat the air used to dry the laundry.
The heater uses an electric blower to draw in outside air. A screen is used to prevent debris in the air from entering
the blower. The air is mixed with JP--8 and ignited to generate a flame inside the heater. The heater exhaust air is
then used to heat thermal fluid that is moving through the heater coil.
The hot thermal fluid is circulated to heat exchangers in the washing/drying drums and still by the thermal fluid pump.
An expansion tank is used to store thermal fluid and provided a place for the fluid to expand when it gets hot. The
tank has a fill port to facilitate servicing of the thermal fluid.
FILL PORT
EXPANSION TANK
HEATER
THERMAL FLUID
PUMP
ELECTRIC BLOWER
FILTER SCREEN
HEATER COILS