TM 10--3510--221--24
0094 00--2
EMERGENCY STOP ACTIVATED -- Continued
0094 00
12. Wait for laundry cycle to be completed.
Was laundry cycle interrupted with another EMERGENCY STOP ACTIVATED fault message?
YES Go to step 13.
NO Return to normal operation.
13. Position SW2 to OFF then back to ON.
14. Check settings on PM800 (WP 0225 00).
Are PM800 settings adjusted properly?
YES Go to step 15.
NO Properly adjust settings. Return to step 10.
15. Continue laundry cycle or start new laundry cycle at both drums (TM 10--3510--221--10).
16. During extracts check for correct voltage level at external power source.
Does voltage remain at or above 208 VAC during extracts?
YES Go to step 17.
NO Correct voltage level at external power source as necessary.
17. Continue laundry cycle or start new laundry cycle at both drums (TM 10--3510--221--10).
18. Check for >200 VAC across CB3 and CB4 output terminals (T1 and T2), (T1 and T3), and (T2 and T3).
Is >200 VAC present?
YES Go to TYPICAL DISCRETE INPUT SIGNAL FAULT (WP 0107 00).
NO Go to step 19.
19. Position SW2 then SW1 to OFF.
20. Check wire connections between CB3, CB4, drum inverters and drum motors.
Are wires and connections OK?
YES Replace drum inverter with low voltage reading in step 18 (WP 0245 00).
NO Repair as necessary.
END OF WORK PACKAGE