AIR COMPRESSOR INVERTER FAULT -- Continued
0098 00
9. Check wire connections between air compressor inverter and air compressor for short circuit.
Are wire connections OK?
YES Go to step 10.
NO Repair as necessary.
10. Check air compressor motor for shorted windings.
Are motor windings shorted?
YES Replace air compressor (WP 0198 00).
NO Replace air compressor inverter (WP 0222 00).
11. Allow air compressor inverter to cooldown for about 30 minutes.
12. Press RESET on inverter keypad.
13. Wait about 30 seconds then observe operator panel display.
Does AIR COMPRESSOR INVRTR FAULT disappear?
YES Go to step 14.
NO Replace air compressor inverter (WP 0222 00).
14. Continue laundry cycle or use maintenance menu to operate air compressor.
Does another air compressor INVERTER FAULT occur?
YES Replace air compressor inverter (WP 0222 00).
NO Return to normal operation.