TM 10--3510--221--24
0100 00--2
NO +12 VDC POWER AVAILABLE -- Continued
0100 00
9. Check for +12 VDC between TB2 terminals where wires (190, 202, 212, 213, 214, 215, and 220 are
connected and (COM) on PS1.
Is +12 VDC present?
YES Go to step 10.
NO Check wire connections between PS1 and TB2. Repair as necessary.
10. Check for +12 VDC between TB2 terminal where wire (191) is connected and (+12) on PS1.
Is +12 VDC present?
YES Check wire connections between TB2 and location where +12 VDC was not found. Repair as
necessary.
NO Check wire connection between PS1 (COM) and TB2. Repair as necessary.
END OF WORK PACKAGE