TM 10--3510--221--24
0111 00--9
LAUNDRY ADVANCED SYSTEM
PREVENTIVE MAINTENANCE CHECKS AND SERVICES -- Continued
0111 00
TABLE 1. Unit PMCS -- Continued.
ITEM
NO.
INTERVAL
MAN--
HOUR
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
8
Annually
Water recycle
system
Inspect welds on still (1), still condenser (2),
and distillate pump frame (3).
Cracks in welds
are present.
Inspect door arms (4) and knobs (5) on still
doors (6) for loose connections.
Arms or knobs
are loose.
Inspect for bent pins (7) on door locks (8).
Ensure pins engage properly with door
arms (4).
Door lock pins
are bent or do
not engage
door arms.
Inspect relief valve piping (9) for security.
Relief valve
piping is loose.
Inspect heat exchangers (10) and
subcooler (11) on still condenser (2) for
bent or damaged fins. Straighten fins if
necessary.
Fins are bent
over blocking
air flow.
Inspect condensate drain plumbing (12)
distillate plumbing loose hose and fitting
connections, rubbing hoses or piping, and
loose clamps.
Connections
are loose,
clamps are
loose, or hoses
and piping are
rubbing.
Inspect steam piping (13) and insulation
(14) between still (1) and still condenser
(2).
Steam piping is
loose or
insulation is
damaged or not
covering piping.
Inspect distillate plumbing (15) for loose
hose and fitting connections, rubbing hoses
or piping, and loose clamps.
Connections
are loose,
clamps are
loose, or hoses
and piping are
rubbing.
Inspect anti--foam supply plumbing (16) for
loose tubing and fitting connections,
rubbing tubing, and loose clamps.
Connections
are loose,
clamps are
loose, or tubing
is rubbing.