TM 10--3510--221--24
0111 00--11
LAUNDRY ADVANCED SYSTEM
PREVENTIVE MAINTENANCE CHECKS AND SERVICES -- Continued
0111 00
TABLE 1. Unit PMCS -- Continued.
ITEM
NO.
INTERVAL
MAN--
HOUR
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
9
Annually
Heating System
Inspect welds on heater frame (1) and
expansion tank (2).
Cracks in welds
are present.
Inspect chimney (3) and extension (4) for
damage.
Chimney or
extension are
loose or bent.
Inspect enclosure (5) for security. Ensure
door (6) seals properly and inside of
enclosure show no evidence of water.
Door does not
seal or water is
entering
enclosure.
Inspect enclosure (5) and conduit (7) for
loose connections, rubbing wires, and loose
clamps.
Connections
are loose,
clamps are
loose, or
conduit or
wiring is
rubbing.
Inspect thermal fluid plumbing (8) for loose
hose and fitting connections, rubbing hoses
or piping, and loose clamps.
Connections
are loose,
clamps are
loose, or hoses
and piping are
rubbing.
Inspect fuel plumbing for (9) for loose
tubing and fitting connections, rubbing
tubing or piping, and loose clamps.
Connections
are loose,
clamps are
loose, or tubing
and piping are
rubbing.
Replace heater fuel filter element
(WP 0176 00).
Filter is