TM 10--3510--221--24
0116 00--1/2 blank
FAN MOTOR CAPACITOR REPLACEMENT
0116 00
THIS WORK PACKAGE COVERS:
Removal, Installation
INITIAL SETUP:
Maintenance Level
Materials/Parts
Unit
Tags (Item 9, WP 0271 00)
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanics (Item 1, WP 0272 00)
LADS power shut off at main control
enclosure (WP 0112 00).
REMOVAL
1. Remove two screws (1), then remove cover (2) and gasket (3) from junction box (4).
2. Tag and disconnect leadwires of capacitor (5).
3. Loosen nut (6) on cord grip (7), then pull lead wires out of junction box (4).
4. Remove jam nut (8) and lock washer (9), then remove capacitor (5) from cover (2).
10
5
1
2
3
9
8
4
6
7
INSTALLATION
1. Position new capacitor (5) on cover (2), then secure with lock washer (9) and jam nut (8).
2. Insert lead wires through cord grip (7) and into junction box (4), then tighten nut (6).
3. Connect leadwires of capacitor (5) as tagged.
4. Install cover (2) and gasket (3) on junction box (4), then secure with two screws (1).
5. Position MAIN DISCONNECT switch (WP 0009 00, Figure 1, 1) to ON. Verify fan (10) is operating.
END OF WORK PACKAGE