TM 10--3510--221--24
0127 00--2
DOOR LOCK POSITION SWITCH
REPLACEMENT --Continued
0127 00
INSTALLATION
1. Close drum door (5) and engage handle (6).
2. Use maintenance menu to access control outputs function (WP 0010 00). Extend door lock DN100.
3. Secure LADS electrical power (WP 0112 00).
4. Thread jam nut (3) onto new position switch (2) so that nut is located at leadwire end of switch.
5. Thread position switch (2) into mounting block (4), by hand, until switch contacts door lock (7).
6. Unthread position switch (2) 1--1/2 turns.
7. Tighten jam nut (3) against mounting block (4) being careful not to change adjustment of position switch (2).
8. Connect electrical cable (1) to position switch (2).
9. Using maintenance menu to access control outputs and examine inputs functions (WP 0010 00), verify correct
operation of position switch (2) as follows:
a. Extend door lock DN100.
b. Verify position switch ZS101 status is ON.
c. Retract door lock DN100.
d. Verify position switch ZS101 status is OFF.
END OF WORK PACKAGE