TM 10--3510--221--24
0168 00--2
RINSE 2 TANK INLET TEMPERATURE SENSOR
REPLACEMENT -- Continued
0168 00
ROTATED 90_
8
6
7
9
5
3
4
1
2
INSTALLATION
1. Connect electrical connector (3) to temperature sensor (4).
2. Access examine inputs function using maintenance menu (WP 0010 00), then observe and record temperature
reading for TE100.
3. Access temperature sensor calibration function using maintenance menu (WP 0010 00), then set output of
temperature sensor TE202 to same temperature reading as recorded for TE100.
4. Slide new nut (5), upper ferrule (9) and lower ferrule (7) onto new temperature sensor (4).
5. Insert temperature sensor (4) into fitting (6) at previously recorded dimension.
6. Tighten nut (5) onto fitting (6) to swage lower ferrule (7) on temperature sensor (4).
7. Loosen nut (5) and remove temperature sensor (4) from fitting (6).
8. Apply pipe thread sealant to threads of fitting (6).
9. Thread fitting (6) into piping (8).
10. Insert temperature sensor (4) into fitting (6) then tighten nut (5).
11. Perform a HEAT WATER operation with a water temperature setpoint of 150 degrees F (TM 10--3510--221--10).
Verify no water leaks exist.
12. Close access door (2) and secure by engaging two latches (1).
END OF WORK PACKAGE