TM 10-3510-222-10
2-8. INITIAL ADJUSTMENTS AND CHECKS.
WARNING
If EMERGENCY SHUTDOWN is required, on generator control panel turn MASTER SWITCH to
OFF. All electrical power to Laundry Unit will be cut off. Failure to observe this warning may
result in serious injury or death to personnel.
WARNING
Ear protection is required when operating the Laundry Unit. Serious hearing loss could occur if
the Laundry Unit is operated without ear protection.
a.
Generator. Refer to TM 5-6115-585-12 for starting procedures and start the generator.
b.
Water Pump. See figure 2-20.
(1)
Remove quick disconnect plug (I) located at the top of pipe tee (2).
(2)
Prime pump with clean water and fill up pipe tee (2) with water.
(3)
Replace quick disconnect plug (1).
(4)
Press temperature/amperage reset button.
(5)
Set toggle switch (3) to ON
2-57