TM 10-3510-222-10
2-7. ASSEMBLY AND PREPARATION FOR USE - continued.
l.
Generator, Dryer, and Water Heater Exhaust Hoses. See figure 2-19.
WARNING
Carbon monoxide is dangerous. Ensure that exhausts are properly vented to an open-air area.
Death or serious injury to personnel can result from heavy exposure to exhaust gas.
(1)
Unhook three exhaust straps (3) and remove metal hose (2) from Laundry Unit.
WARNING
Be sure that exhaust ducts do not touch or cross other exhaust ducts, power cables, fuel lines,
or water hoses. Melting/damage can occur causing leaking fuel and water or electrical hazards
Death by electrocution, fire, or explosion could result.
(2)
Connect 5-inch (126 mm) metal hose (2) to dryer exhaust port elbow (6) and thro ugh bracket (1). Extend
metal hose away from Laundry Unit.
NOTE
The dryer air duct hose is stored inside the dryer assembly during transportation.
(3)
Install 12-inch (305 mm) air duct hose (5, sheet 2) on dryer exhaust duct adapter (discharge) (4, sheet 2).
Fully extend air duct hose (5, sheet 2) along curb side of trailer
(4)
Connect two 7-inch (178 mm) burner exhaust ducts (7, sheet 2) together and connect to water heater
exhaust port. Extend duct full length away from rear of trailer.
(5)
Connect two 2-inch (51 mm) generator exhaust hoses (8, sheet 2) to generator exhaust ports. Extend
ducts away from trailer assembly.
2-54