TM 10-3510-222-24
2-51. SHUTTER.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools
Equipment Condition
General Mechanic's Tool Kit (App B, Item 1)
Dryer shut down (TM 10-3510-222-10)
Rotary Pump removed (Para 2-53)
a. REMOVAL
(1)
Remove four screws (1), lockwashers (2) and adapter (3) from blower assembly (7).
(2)
Loosen screw (4) and remove cover (5) from adapter (3).
(3)
Remove screen (6).
b. INSTALLATION
(1)
Position screen (6) into adapter (3).
(2)
Position adapter (3) on blower assembly (7) and secure with four lockwashers (2) and screws (1).
(3)
Position cover (5) on adapter (3).
(4)
Adjust cover (5) for maximum open position on adapter (3) and tighten screw (4).
(5)
Install rotary pump (Para 2-53).
2-122