TM 10-3510-222-24
Table 2-5. UNIT DRYER TROUBLESHOOTING PROCEDURES
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
DRYER FAILS TO START.
Check for voltage to START/STOP RESET BUTTON.
a.
Apply electrical power, refer to generator TM 5-6115-585-12.
b.
Remove electrical power, refer to TM 5-6115-585-12.
c.
Notify Direct Support.
2.
DRYER FAILS TO DRY LAUNDRY
Notify Direct Support.
3.
DRYER BURNER FLAME FAILS.
Step 1. Check for nonmetallic hose(s) leaking.
If nonmetallic fuel hose(s) are leaking, repair per paragraph 2-43, Nonmetallic Hoses.
Step 2. Check for defective rotary pump.
If rotary pump is defective, replace rotary pump. Refer to paragraph 2-53, Rotary Pump.
Step 3. Check for defective fuel solenoid.
If fuel solenoid is defective, replace fuel solenoid. Refer to paragraph 2-70, Solenoid Nonmetallic Hose
Valve.
2-25