TM 10-3510-222-24
Table 2-6. UNIT EXTRACTOR TROUBLESHOOTING PROCEDURES - continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
EXTRACTOR FAILS TO START.
Check for voltage.
a.
Apply electrical power, refer to TM 5-6115-585-12.
b.
Remove electrical power, refer to TM 5-6115-585-12.
c.
If voltage exists, notify Direct Support.
2.
EXTRACTOR STARTS BUT BASKET FAILS TO TURN.
Step 1. Check for slipping, broken or missing drive belt or pulley.
If drive belt is slipping, broken or missing, replace belt. Refer to paragraph 2-42, Motor Assembly.
Step 2. Check for foreign material or clothing wrapped around shaft, above and below the basket.
a.
If obstruction is found, remove clothing or foreign material.
b.
If problem persists, notify direct support.
3.
EXTRACTOR FAILS TO DRAIN.
Check for a clog in the drain inside the extractor.
If the drain is clogged, unclog the drain.
2-28