TM 10-3510-223-13&P 0002 00
0002 00-2
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS (Internal)
Container. Modified type III general cargo container (1) with forklift pockets (2) and ISO fittings (3) for
moving and lifting the container. Double doors are located at each end of the container. The personnel
door (4) serves as main access door to the CSSL, and the rear door (5) provides access to the fresh
water pump (6), wastewater tank (7), and pressure tank (8). An additional double service door (9) at the
curbside allows access to the rear of the washer/dryers (10). Built-in, folding steps (11) and a grip atop the
container (12) allow access to the top of the container.
Vent fan. Installed in the container roof, the fan (13) ventilates the interior of the CSSL container (1).
Space heater. Installed in the container curbside rear end, the heater (14) provides interior heating of the
container when the CSSL is not in operation.
Power entrance box. The box (15) is located on the roadside and includes two 208VAC, 3 Phase input
connectors (16) for power supply to both circuit breaker panels 1 (17) and 2 (18), a 120VAC GFCI
receptacle (19) used for TEMPER interior lights, and a 3 Phase, 208 VAC output receptacle (20) used for
external components.
Power distribution panel #1 (17). Panel #1 contains a main breaker, and powers washers/dryers (10)
#1,
,3
,and 5
, CSSL interior lights (21), the alarm circuit (22), the space heater (14), the interior
GFCI circuit (23), the fresh water pump (6), the exterior GFCI circuit (19) and a phase indicator.
Power distribution panel #2. (18) Panel #2 contains a main breaker, and powers washer/dryers (10) # 2
4
, and 6
, as well as the 60 AMP, 208VAC output circuit (20).
Freshwater and wastewater panels. Panels for water supply (24) and wastewater drain (25) hose
connection between inside and outside CSSL are located in the curbside wall. Panels facilitate the
following connections:
=
Outside CSSL: Fresh water connection and wastewater connection to external source and
disposal point, respectively.
=
Inside CSSL: Fresh water connection to the fresh water pump, and wastewater connection from
the wastewater holding tank. A small diameter drainpipe exits through the container floor.
Interior fluorescent lights and light switch. Two fluorescent light fixtures (21) are controlled from the
light switch (26) located on the roadside wall.
Washers/Dryers (10). The washer/dryers are mounted to the container floor and wall. The power cord
(27) of each washer/dryer unit is plugged into the twist-lock receptacles (28) located on the overhead
raceway. Two fresh water hoses (29) connect each washer to the ¾ fresh water supply line (30). The
washer drain hoses (31) are connected to the 3 PVC drainpipe (32).
Freshwater pump. The freshwater pump (6) is mounted onto the container floor and is connected to the
fresh water supply panel. It provides fresh water pressure to the main supply line when a 3,000 Gallon
storage tank is used. A freshwater pump cover (32) is bolted to the floor and encloses the pump housing.
b
a
c
e
d
f