TM 10-3510-223-13&P 0002 00
0002 00-6
EQUIPMENT DATA
The following data pertains to the CSSL. Comparable data for the TEMPER, the water pump, wastewater
ejector pump, and the commercial washer/dryers is contained in the appropriate equipment publications
shown on page 0002 00-8.
External dimensions:
Length.................................................. 19 feet, 10-1/2 inches ...........................6.06 meters
Width ................................................................ 8 feet.........................................2.44 meters
Height ............................................................... 8 feet.........................................2.44 meters
Internal dimensions:
Length...................................................... 19 feet, 4 inches ............................... 5.80 meters
Width ........................................................ 7 feet, 6 inches ................................ 2.25 meters
Height .................................................... 7 feet, 3-3/8 inches ............................. 2.18 meters
Door dimensions:
Personnel entrance door (front)
Height .............................................6 feet, 11-5/8inches............................. 2.09 meters
Width ................................................. 7 feet, 7 inches ................................ 2.28 meters
Double service door (curbside)
Height .............................................6 feet, 11-5/8inches...................... 214 centimeters
Width ............................................. 7 feet, 7 inches 96.5 ............................ centimeters
Double service door (rear)
Height ............................................ 6 feet, 11-5/8 inches ............................ 2.09 meters
Width ................................................. 7 feet, 7 inches ................................ 2.28 meters
Weight:
Modified (CSSL), packed for movement 10,000 pounds ...................... 4536 kilograms
Required electrical input:
CSSL ..................................................................... ..................100 Amp, 208 VAC, 3 Phase
Washers/Dryers..................................................... ............................30 Amp, 120/208 VAC
Wastewater pump ................................................. ............20 Amp, 208 VAC, Single Phase
Heater, space ........................................................ .............30 Amp, 120/208 VAC, 3 Phase
Fan, vent................................................................ .....................20 Amp, 208VAC, 3 Phase
Lights, fluorescent ................................................. ...................................20 Amp, 120 VAC
Pump, freshwater .................................................. ............20 Amp, 208 VAC, Single Phase
External GFCI........................................................ ...................................20 Amp, 120 VAC
Power output ......................................................... ....................20 Amp, 208 VAC, 3 Phase
Pressure Tank Setting:
Low ....................................................................... .....................................................20 PSI
High ...................................................................... ...................................................120 PSI
Required fresh water flow rate: .................. 20 gallons/minute ......................... 76 liters/minute
Environmental:
Operating temperature range ............. 320 to 1200 Fahrenheit .............. 00 to 490 centigrade
Maximum operating elevation........................ 7000 feet.....................................2114 meters