TM 10-3510-223-13&P
0036 00
CONTAINERIZED SELF SERVICE LAUNDRY (CSSL) MODEL A
DIRECT SUPPORT MAINTENANCE
0036 00-1
INTERNAL FRESHWATER LINE
THIS SECTION COVERS:
Repair
INITIAL SETUP
CSSL not in operation
Maintenance Level
Direct Support
Tools and Special Tools
Materials/Parts
Tool Kit, Org. Maintenance, Common No.1
(WP 0044, Table 2, Item 2)
Cleaner, All-purpose (WP 0072, Table 1, Item 9)
Solder, Lead Free (WP 0072, Table 1, Item 6)
Pipe Wrench 18 (WP 0045, Table 2, Item 4)
Wiping Rags (WP 0072, Table 1, Item 1)
Pipe Wrench 10 (WP 0045, Table 2, Item 5)
Tape, Antiseize (WP 0072, Table 1, Item 3)
Tube Cutter. (WP 0045, Table 2, Item 6)
Cement All-purpose (WP 0072, Table 1, Item 8)
REPAIR
Disconnect the freshwater supply hose from the freshwater input panel before repairing any portion or
part of the ½ or ¾ inch internal copper freshwater line. Connect a garden hose to the fitting at the end of
the freshwater line, open gate valves on the freshwater line, and let the line drain. Repair any leaks or
malfunctioning components in the line as described below.
Repair a leak in any seamless pipe section by soldering. Replace a gate valve (1), pressure relief valve
(2), ball valve (3), hose adapter fitting (4), water flow control fitting (5), Tee (6), adapter fitting (7), or elbow
fitting (8) by heating the solder joint until the solder is liquefied. Remove the component. Solder a new
component securely into place. (Refer to work package 0055 to identify pipe section components)
NOTE
If the freshwater pump cover must be removed to access to any portion
of the freshwater line to be repaired, remove the cover as described in
work package 0034.
Replace the pressure gage (9) by unscrewing the hex nut (10) from the freshwater line (11). Remove the
pipe section from the faulty gage and install onto new gage, applying antiseize tape to the threads. Install
a new gage (9) onto the freshwater line (11) by tightening the hex nut (10).
Repair a freshwater line retainer bracket (12), by replacing the wall plate (13), the rod mount split-ring
hanger (14), the threaded rod (15), the pipe cushion (16) or the wood screw (17), holding the bracket to
the floor.
Repair the PVC supply line (18) between the freshwater pump and the freshwater inlet panel by cutting
out a leaky or damaged section and replacing with a similar, new section. (Refer to work package 0055
00 to identify PVC supply line components) Clean the ends of both connecting sections with all-purpose
cleaner, and cement the sections together. Follow product instructions for the use of the all-purpose
cement.