TM 10-3510-233-13&P
0003 00
0003 00-5/6 Blank
CSSL MINIMUM EMPLOYMENT CONDITIONS
Following is a summary of the conditions and parameters required to employ a CSSL.
Material Handling Equipment
A 10,000 lbs lifting and moving device (i.e., forklift, etc.) is required to unload and position the packed
CSSL container.
Area Characteristics and Dimensions
A level area of approximately 2,000 square feet is required. The ground must be free of obstacles and
vegetation (trees, brush, etc.) so that the container sits firmly on the ground. If the 3000 gallon freshwater
or wastewater tanks are used, vehicular access is required. The employment area elevation should not
exceed 7,000 ft (2114 Meters)
Power Requirements
The CSSL requires 100AMP, 208VAC, 3 Phase power. This can be provided through a commercial
hookup, or through use of a generator (30 KW minimum). The power connection must be made by
qualified civilian or military (MOS 51R, 52C, 52D, or 52G) personnel.
Utility Requirements
A freshwater source supplying a maximum 8,700 gallons per 20 hour period (Consumption at full use) is
required. The source should be either a municipal water system or another approved freshwater water
source.
Wastewater Disposal
A wastewater disposal site must be available in the form of a municipal sewage system, or other approved
site where the wastewater collected in the 3,000 Gallon wastewater tank can be evacuated.
Water Service
If 3,000 Gallon tanks are used for fresh and/or wastewater, water supply trucks (or service) and/or
wastewater pumping tank trucks (or service) are required. Approximately three supply and collection
round trips are required per day to keep the CSSL in full operation.