8. Before placing the CSSL in operation, test the operation of each washer/dryer by briefly activating the controls,
and if the machine starts, resetting the controls. The CSSL is protected during long-term storage with non-toxic
antifreeze. After testing, operate each washer for one complete regular cycle, to evacuate any residual antifreeze prior
to using the laundry for clothing. After purging, operate washer/dryers as described in posted instructions.
9. To operate the space heater, set the circuit breaker # 15 in the Right Side Power Distribution Panel to ON and
adjust the heater control knob until the heater comes on. The heater should not be operated while the washers and
dryers are in operation.
10. Operate vent fan, by turning toggle switch located on the Right Side Power Distribution Panel to INTAKE or
EXHAUST.
To operate the 3,000 Gallon collapsible fabric tank(s) refer to TM 5-5430-237-12&P. Operate the TEMPER as
described in TM 10-8340-224-13.
During operation of the CSSL, frequently check the exterior dryer exhaust vent for free air flow.
CSSL TEMPORARY SHUTDOWN.
If the CSSL will not be needed for an extended period, it should be shut down temporarily.
NOTE
If the CSSL needs to be shut down because of unusual weather conditions, refer
to work package 0006 00.