TM 10-3510-224-13&P
0005 00
Using a 3,000 Gallon freshwater tank:
1. Shut off the freshwater pump (1) by setting circuit breaker # 3 in the Right Side Power Distribution Panel to OFF.
Disconnect the 2 freshwater hose (2) from the freshwater inlet panel (3) on the utility wall. While holding the end of the
hose above the water level in the freshwater tank (4), place the end of the hose (2) into the freshwater tank as shown.
Install dust cap (5) on panel (3).
2. Connect garden hose to the hose fitting (6) located at the end of the supply line (behind washer/dryer #6) and
open (handle in line with water line) the ball valve (7). Leave the valve open after system has drained. Disconnect
garden hose, drain and coil it, connect the ends together and set it aside.
3. Drain the 3,000 Gallon freshwater tank (4) in accordance with TM 5-5430-237-12&P. Remove the 2 freshwater
hose (2) from the freshwater tank. Drain the hose, coil, and set it aside.
4. Place the coiled garden hose inside the CSSL. Coil and place 2 freshwater hose (2) together with 3,000 gallon
freshwater tank (4) inside CSSL.
PREPARE WASTEWATER COMPONENTS FOR SHIPMENT.
WARNING
Avoid spillage of wastewater. Drain wastewater hoses into an approved disposal
facility. Keep wastewater hoses away from freshwater hoses and any freshwater
supply in the vicinity. Serious health problems may result from freshwater
contamination.
Using a municipal disposal system:
1. After the sump pump (8) has stopped running, shut off the pump (Circuit Breaker #12, Right Side Power
Distribution Panel).
2. Disconnect the 2 wastewater hose (9) from the wastewater panel (10) on the utility wall, and drain it into the
disposal point. Disconnect 2 wastewater hose (9) from wastewater disposal point. Drain the hose, coil and set it aside.
Using a 3,000 Gallon wastewater collection tank:
1. Disconnect the 2 wastewater hose (9) from the wastewater panel (10) on the utility wall and hold the end of the
hose above the water level in the 3,000 Gallon wastewater tank (11). Place the end of the hose into the wastewater
tank as shown.
2. Empty the 3,000 Gallon wastewater tank (11) in accordance with TM 10-5430-237-12&P. Remove the 2
wastewater hose (9) from the wastewater tank. Drain the hose, coil, and set it aside.
3. Clean out dryer lint traps (12) and dispose of lint. Clean CSSL and TEMPER as described in work package 0010
00.
0005 00-39