Table 1. Automatic Soap Dispenser Troubleshooting Procedures for
Containerized Batch Laundry Continued.
MALFUNCTION
CORRECTIVE ACTION
TEST OR INSPECTION
6. No product feed
Ensure the boiler is operating
Operate CBL IAW TM 10-3510-
correctly, and hot water supply
226-10. Open valve.
valve V-60 (Figure 8, Item 1) is
open.
Ensure valves V-39 (Figure 9,
Open valves.
Item 2) and V-40 (Figure 9, Item
3) are open.
Check nozzles (Figure 9, Item 4)
Unscrew nozzles, and clean or
for obstructions or damage.
replace as necessary.
Apply a signal to the Automatic
If no LED, replace control module
Soap dispenser by running a
routine cycle. Monitor the LED
lights (Figure 10, Item 5) on high
voltage input board (Figure 10,
Item 6).
If further corrective action is
required, notify direct support
maintenance.
1
Figure 8. No Product Feed.
0009 00-9