Table 1. Dryer Troubleshooting Procedures for Containerized Batch Laundry.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. No electrical power to
equipment
WARNING
WARNING
The equipment being tested or
The equipment being tested or
corrected operates at voltage and
corrected operates at voltage and
current that can cause serious injury or
current that can cause serious
death.
injury or death.
Check all electrical cables (Figure 1,
Item 1) for proper connection.
Check for power at cable connections.
If no power is present, check
power source.
Check circuit breakers (Figure 2, Item
Reset breakers. Then, test or
2).
replace the breaker, if necessary.
Check phase monitor relays (Figure 2,
Test and replace fuses (Figure 2,
Item 4) as
necessary IAW WP
Item 3)
Test and replace relay as
If further corrective action is
required, notify direct support
maintenance.
1
Figure 1. No Electrical Power to Equipment.