TM 10-3510-226-23
0058 00
REPLACE-CONTINUED
Replace the Automatic Soap Dispenser Control Module
WARNING
Ensure that all electrical power to the automatic soap dispenser is shut off and
disconnected before proceeding. The circuit breaker box should be locked by personnel
following this procedure. Serious injury or death can result from electrocution if proper
safety precautions are not observed.
1. Disconnect power to automatic soap dispenser.
2. Open control module box (Figure 7, Item 8).
3. Tag and disconnect wiring from control module (Figure 7, Item 8).
4. Remove chart stop relay (Figure 7, Item 9) and retain for installation in replacement control module.
5. Remove conduit locknut, and remove conduit (Figure 7, Item 10) from box.
6. Remove fasteners retaining box to mount and remove control module (Figure 7, Item 8).
7. Open replacement control module (Figure 7, Item 8).
8. Install chart stop relay (Figure 7, Item 9) in replacement control module (Figure 7, Item 8).
9. Install replacement control module (Figure 7, Item 8) and retain with fasteners.
10. Install conduit (Figure 7, Item 10) and retain with locknut.
11. Connect wiring as tagged.
NOTE
The replacement control module will be equipped with an adjustment knob. This should
be removed and discarded before placing the CBL back in normal operation.
12. Close control module (Figure 7, Item 8), connect power, and monitor for normal operation.
0058 00-11