Replace the Thermostat
WARNING
Ensure that all dryer electrical power is shut off and disconnected before proceeding.
The circuit breaker box should be locked by personnel following this procedure. Serious
injury or death can result from electrocution if proper safety precautions are not observed.
1. Disconnect power by switching the dryer circuit breaker to OFF.
2. Remove lint panel.
3. Remove screws retaining thermostat bracket (Figure 11, Item 6) assembly and remove thermostat
and bracket as an assembly.
4. Remove screws retaining thermostat guard (Figure 11, Item 7) and remove guard.
5. Tag and disconnect wiring from thermostat (Figure 11, Item 5).
6. Remove screws retaining thermostat (Figure 11, Item 5) to bracket (Figure 11, Item 6) and remove
thermostat.
7. Install replacement thermostat (Figure 11, Item 5) onto bracket (Figure 11, Item 6) and retain with
screws.
8. Connect wiring to thermostat (Figure 11, Item 5) as tagged.
9. Install thermostat guard (Figure 11, Item 7) and retain with screws.
10. Install thermostat (Figure 11, Item 5) and bracket (Figure 11, Item 6) as an assembly and retain with
screws.
11. Install lint panel.
12. Switch the circuit breaker to ON and monitor for normal operation.