TM 10-3510-226-23
0067 00
REPLACE-CONTINUED
6. Remove screws retaining fan housing cover (Figure 5, Item 11).
7. Remove bolts securing guard (Figure 5, Item 12), and remove guard.
8. Remove bolts securing motor (Figure 5, Item 9) to motor mount, and remove motor, fan (Figure 5,
Item 9, 13), and fan housing cover (Figure 5, Item 11) as an assembly.
9. Secure the motor shaft and remove the nut retaining the fan (Figure 5, Item 13) to the motor shaft
(Figure 5, Item 14).
10. Remove the bolts retaining the fan housing cover (Figure 5, Item 11) to the motor (Figure 5, Item 9).
11. Remove the fan (Figure 5, Item 13) and the fan housing cover (Figure 5, Item 11) from the motor
shaft (Figure 5, Item 14). Remove the key (Figure 5, Item 15) from the motor shaft.
12. Install the key (Figure 5, Item 15) on the replacement motor shaft (Figure 5, Item 14).
13. Install the fan housing cover (Figure 5, Item 11) onto the motor shaft (Figure 5, Item 14).
14. Install the fan (Figure 5, Item 13) onto the motor shaft (Figure 5, Item 14) and retain with nut.
15. Secure the fan housing cover (Figure 5, Item 11) to the motor (Figure 5, Item 9) with bolts.
16. Install the motor (Figure 5, Item 9), fan (Figure 5, Item 13), and fan housing cover (Figure 5, Item
11) as an assembly onto the motor mount and retain with bolts.
17. Install the guard (Figure 5, Item 12) and retain with bolts.
18. Retain the fan housing cover (Figure 5, Item 11) to the dryer with screws.
19. Remove screws retaining motor junction box cover (Figure 4, Item 8), and remove cover.
20. Install the conduit (Figure 4, Item 10) with wiring into the motor junction box (Figure 4, Item 8).
21. Connect the wiring to the motor (Figure 4, Item 9) as tagged.
22. Install the motor junction box cover (Figure 4, Item 8) and retain with screws.
23. Install the belts IAW procedures given in WP 0066 00.
24. Connect power, operate IAW procedures given in TM 10-3510-226-10, and monitor for normal
operation.
0067 00-8