11. Swing transformer (Figure 8, Item 6) back into place and retain with screws.
12. Connect power, operate IAW procedures given in TM 10-3510-226-10, and monitor for normal
operation.
15
7
8
8
1
in.
9
15
Figure 8. Replace the Burner Electrodes.