TM 10-3510-226-23
0069 00
REPLACE-CONTINUED
WARNING
Ensure fuel is contained and not allowed to spill or spray into the CBL. Failure to observe
safety precautions may result in a fire, with the possibility of serious injury or death to
personnel.
1. Disconnect power by switching circuit breaker No. 22 to OFF.
2. Remove bolt (Figure 12, Item 20) retaining filter housing (Figure 12, Item 21) to filter canister
(Figure 12, Item 22), and lift filter housing off of canister.
3. Remove and discard fuel filter (Figure 12, Item 23) from filter canister (Figure 12, Item 22). Install
replacement filter into filter canister.
4. Ensure gasket is in place, and install filter housing (Figure 12, Item 21) onto filter canister (Figure
12, Item 22).
5. Retain with bolt (Figure 12, Item 20), and tighten.
6. Wipe any residual fuel from filter housing (Figure 12, Item 21) and filter canister (Figure 12, Item
22).
7. Connect power, bleed fuel pump, and monitor for normal operation.
20
23
21
22
0069 00-21