TM 10-3530-207-14
Table 3-1.
Operator Troubleshooting - continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
CABINET ASSEMBLY
3.
REAR DOOR OR SIDE DOOR DOES NOT CLOSE.
Inspect door for the same defects as malfunction No. 2.
4.
REAR OR SIDE DOOR WILL NOT STAY IN OPEN POSITION.
Check door stays for mechanical binding and loose or missing door stay mounting brackets.
Notify next higher level of maintenance if door stays will not lock into position due to binding or loose or missing
mounting brackets.
5.
SEWING MACHINE HEAD IS LOOSELY MOUNTED IN TRAY.
Step 1. Check that tray strap assembly hold down strap is tight. Tighten strap.
Step 2. Check that tray strap footman loop (on tray) is not loosely mounted. If strap footman loop is
loose, notify next higher level of maintenance.
6.
STOWAGE BOX DOES NOT CLOSE SECURELY.
Step 1. Check that stowage box hinge is not bent or broken. If hinge is bent or broken, notify next higher
level of maintenance.
Step 2. Check that stowage box latch and latch hook are not deformed or broken. If latch or latch hook
are deformed or broken, notify next higher level of maintenance.
7.
GENERATOR IS LOOSELY MOUNTED ON SLID ES.
Step 1. Check that the rear generator holddown bracket is in place and secure. Install rear holddown
bracket.
Step 2. Check that the front generator holddown is not cracked or broken. If holddown is damaged,
notify next higher level of maintenance.
3-10