TM 10-3530-207-14
Table 3-1. Operator troubleshooting - continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
CLOTHING SEWING MACHINE
Step 3. Check that light bulb is not broken, burned out, or missing.
If light bulb is burned out, missing, or broken, replace light bulb.
Step 4. Unplug light cord from outlet and check cord and plug for frayed or broken insulation and
wires.
If defective insulation, wiring, or plug is found, notify next higher level of
maintenance.
Step 5. Lamp assembly or lamp ON-OFF switch may be defective.
Replace lamp assembly (para. 3-12).
Step 6. Electrical power outlet receptacle may be defective.
Notify next higher level of maintenance.
21.
MOTOR DOES NOT START.
Step 1. Check motor ON/OFF switch.
Set motor ON/OFF switch to ON position.
Step 2. Check that motor power cable is plugged into distribution power outlet.
Plug power cable into distribution power outlet, (para. 2-8n).
Step 3. Motor ON/OFF switch may be defective.
Notify next higher level of maintenance.
Step 4. Motor may be defective.
Notify next higher level of maintenance.
3-19