TM 10-3530-207-14
Table 3-1. Operator troubleshooting - continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TACK-BUTTON ATTACHING MACHINE
50.
DOUBLE-PRONGED TACK DOES NOT FIT PROPERLY INTO HOLES IN BUTTON.
Check that tack is properly installed in lower die.
Install tack in lower die properly.
51.
MACHINE CUTS MATERIAL.
Check pinch adjustment.
Pinch adjusted too tight. Adjust pinch properly (para. 2-15b).
52.
SHANK OF LOWER DIE BINDS.
Pin on lower die is interfering with spring.
Notify next higher level of maintenance.
HEAT SEALING MACHINE
53.
MACHINE DOES NOT HEAT.
Step 1. Check ON/OFF switch.
Set ON/OFF switch to the ON position (para. 2-16a).
Step 2. Be sure unit is plugged in.
Plug heat sealer into the outlet (para. 2-8n).
Step 3. Unplug heat sealer from outlet and check cord and plug for frayed or broken insulation
and wires.
If defective insulation, wiring, or plug is found, notify next higher level of
maintenance.
Step 4. Heat sealing machine or ON/OFF switch may be defective.
Notify next higher level of maintenance.
3-33