TM 10-3530-207-14
4-60. DISTRIBUTION BOX MAINTENANCE - continued.
Removal.
WARNING
Disconnect the power cable from all equipment prior to beginning any cleaning or testing.
(1)
Remove four topping screws (1) and the receptacle cover (2).
(2)
Tag and disconnect all internal wiring (3) to the receptacles (4).
(3)
Unscrew and loosen the connector (5).
(4)
Remove the cable (6) from the electrical box (7).
(5)
Remove the male plug (8) from the cable (6).
4-151