TM 10-3530-207-14
5-13. GENERATOR SUPPORT RAIL MAINTENANCE - continued.
Inspection - continued.
(2)
Inspect holddown for cracks, elongated holes, and rust/corrosion.
(3)
Inspect track for cracks, elongated holes, and rust/corrosion.
(4)
Inspect pin on track for function, cracks, and rust/corrosion.
Repair Repair of the generator track is limited to the following:
Replacement of the damage pin as follows:
(1)
Drill out and remove rivet (1) securing the pin (2) to the generator track (3).
(2)
Install new pin assembly (2) with a new rivet (1) and secure it to track (3).
5-24