TM 10-4510-208-13&P
0002 00
LOCATION AND DESCRIPTION OF MAJOR COMPONENTS (EXTERNAL)
The major external components of the Containerized Shower and the Shower, Enclosed Unit, System are
described in the following paragraphs.
Container
Both models are housed in standard ISO type 20-feet x 8-feet x 8-feet containers (refer to TM 55-8115-
204-23&P). The shower modifications do not affect the container's external dimensions or transportation
characteristics. In a shipping configuration the total weight is less than 10,000 lbs.
Water Service Panel
The water service panel (1) on the Containerized Shower is located on the side of the container and
consists of 1-inch QDC hot water, -inch QDC cold water, and 2-inch QDC drain hose fittings. The water
service panel (1) on the Shower, Enclosed Unit, System is located at the rear of the container, in the lower
left corner, and consists of 1-inch QDC hot water and -inch QDC cold water fittings. The graywater
discharge fitting (2) is located on the side of the container opposite the folding steps fitted to access the
Double Entry Service Door (Containerized Shower only)
The double entry service doors (3) allow access to the rear of the Containerized Shower, specifically for
removal of the M-80 water heater and the 30 gpm water pump.
Circuit Breaker Panel (Containerized Shower only)
The circuit breaker panel (4) fitted to the Containerized Shower is located above the power service panel
(5). The standard commercial panel contains breakers for the internal and external circuits of the
Containerized Shower as follows:
Table 1. Circuit Breakers.
Circuit Breaker Panel Controls and Indicators (Containerized Shower only)
CIRCUIT
ITEM
FUNCTION
BREAKER NO.
1
Circuit Breaker 20A, 1 Pole
110V AC, Interior Lights
2/4/6
Circuit Breaker 20A, 3 Poles
208V AC 3 phase, M-80 Water Heater and
30 gpm Water Pump
3/5
Circuit Breaker 20A, 2 Poles
208V AC, Space Heater
7/9/11
Circuit Breaker 60A, 3 Poles
208V AC 3 phase, Main Breaker
8
Circuit Breaker 20A, 1 Pole
110V AC, Sump Pump
10
Circuit Breaker 20A, 1 Pole
12
Circuit Breaker 20A, 1 Pole
110V AC, GFCI Convenience Outlet
M-80 Water Heater
In the Containerized Shower shipping configuration, the M-80 water heater (6) is mounted on the
equipment mounting platform located above the graywater holding tank, and is secured with straps. In the
Shower, Enclosed Unit, System shipping configuration, the M-80 water heater is packed as a component
of Force Provider packing plans 4A and 4E. Refer to TM 10-4520-259-13&P.
0002 00-5