TM 10-4510-208-13&P
0002 00
30 gpm Water Pump (Containerized Shower only)
The 30 gpm water pump (7) is mounted on the equipment mounting platform located above the graywater
holding tank and secured with straps.
TEMPER
The TEMPER (8) houses the shave stands (9). Refer to TM 10-8340-224-13 for a description of the
TEMPER tent system. In the deployed configuration, the TEMPER tent section is attached to the
personnel entry end of the shower using a modified end section (bootwall) (10). The Containerized
Shower employs a 16-foot TEMPER assembly stored within the container when not in use. The Shower,
Enclosed Unit, System employs a 32-foot TEMPER assembly packed as a part of Force Provider packing
plan 4B.
Shave Stand
Two shave stands (9) are provided with the Containerized Shower. Four shave stands are provided with
the Shower, Enclosed Unit, System (not all are shown on the illustration). In the deployed configuration
they are set up in the TEMPER tent (8). Each shave stand provides three users with individual sinks, hot
and cold water faucets, a mirror, and an individual overhead light. The shave stand water supply and
graywater drainage are provided by QDC fittings located at the personnel entrance end of the container.
In the Containerized Shower configuration, the disassembled shave stands are stored in the aisle between
the shower stalls inside the container. In the Shower, Enclosed Unit, System configuration, the shave
stands are packed as a component of Force Provider packing plans 4A and 4E.
Power Service Panel
The power service panel (5) for the Containerized Shower is located beneath the circuit breaker panel (4)
and contains a 60A, 208V AC, 3-Phase main power input socket. One 20A socket provides power to the
exhaust fan, and is electrically connected to the fan control switch located at the personnel entrance. A
second 20A socket provides power to the M-80 water heater and 30 gpm water pump. An external type,
double 110V AC GFCI convenience outlet provides power to the shave stands and the TEMPER internal
lighting. The power service panel (5) on the Shower, Enclosed Unit, System is located at the rear of the
container at the upper right corner. It consists of three 20A sockets. The power supply for the fan and
sump pump is plugged into the center socket. The fan is plugged in the right socket, and the power supply
for the lights is plugged into the left socket.
Grounding Terminal (Containerized Shower only)
A container grounding terminal (11) is located on the power service panel. When the Containerized
Shower is supplied with grounded generator power no separate grounding of the container is required.
However, if commercial or another ungrounded power source is used, the container must be grounded
using a grounding rod (12) that is connected to the terminal. The Shower, Enclosed Unit, System is
grounded as a Force Provider component.
3000 Gallon Freshwater Storage Tank (Containerized Shower only)
The storage tank (13) serves as system freshwater supply tank for the Containerized Shower. This
storage tank is not required when the Containerized Shower is deployed as part of the Force Provider
System, or is connected to an authorized alternate source of fresh water.
TEMPER Bootwall
The bootwall (10) is a modified end section that is used to attach the TEMPER tent section (8) to the
personnel end of the container.
0002 00-6