TM 10-4510-208-13&P
0005 00
Move the TEMPER Section Into Position
WARNING
The assembled TEMPER is heavy. At least ten persons are required to move the 16-foot
TEMPER into position. Personnel should be placed at each arch leg and at each base
purlin. Additional personnel, if available, should be stationed at base purlins.
CAUTION
The TEMPER must be lifted evenly in order to prevent twisting the frame. Failure to do
so may result in frame and fabric damage to the entire TEMPER assembly.
1. Using two soldiers at each arch assembly (1) and one at each base purlin, pick up and move the
TEMPER section against the container, centering the ridge on the TEMPER section with the center of
the closed personnel doors.
2. Have two soldiers access the top of the container using the hinged steps (2). Pull the boot (3) over
the container end and lay loosely on the container roof. Locate two bootwall lines (4) attached to the
bootwall fabric and pull them towards the opposite corners of the container as shown. Fasten the
lines to the ISO fittings (5).
3
1
4
5
2
0005 00-27