TM 10-4510-208-13&P
0035 00
10. Repeat steps 5 through 8 on adjacent shower valves and showerhead as necessary to allow
movement of the piping.
11. Use a hacksaw to cut the pipes attached to the shower valve.
WARNING
Soldering and unsoldering require the use of an open flame, which can burn skin and
eyes. Keep open flame away from combustible materials. Failure to observe safety
precautions may result in fire or serious injury to personnel.
12. Unsolder faulty shower valve (11) from water lines (12) by applying a torch to the pipe adjacent to the
fitting. Remove valve from fascia plate assembly.
Cut here
12
10
9
11
8
7
5
6
4