TM 10-4510-209-13&P
0005 00
Connect Freshwater Hose
After receiving authorization from Force Provider water distribution personnel, lay out the water supply as
follows:
NOTE
Position the hose away from areas where it may sustain damage from foot or vehicular traffic.
1. Connect the 1-inch Tee assembly (1) to the Force Provider water distribution leg.
NOTE
Do not connect the hose to the lower freshwater inlet fitting at this time. This fitting is used to
flush the wastewater holding tank prior to maintenance, movement, or storage.
2. Connect one end of a 1-inch x 20-foot hose to the upper freshwater input fitting (2) located at the
rear of one CL and the other end of the hose to the 1-inch Tee assembly (1).
3. Connect one end of another 1-inch x 20-foot hose to the upper freshwater input fitting (2) located at
the rear of the other CL and the other end of the hose to the 1-inch Tee assembly (1).
2
1
0005 00-16