TM 10-4510-209-13&P
0066 00
NOTE
The replacement ECU may be installed in the cabinet of the inoperative ECU, provided
both are the same model, and no material damage or corrosion is present on the older
cabinet.
8. Repeat steps 3. through 5. on the replacement ECU (4).
9. Drill the cabinet (6) of the replacement ECU (4) to accommodate the ECU carrier (7).
10. Install the ECU carrier (7) on the cabinet (6) of the replacement ECU (4).
11. Connect the ECU cabinet ground to the ECU cabinet (6).
12. Install the ECU cabinet (6) onto the ECU (4), and retain with screws and washers.
13. Place ECU (4) into position on ECU tray (5).
14. Install faceplate (1).
15. Connect ECU power cord (1) into supply outlet (2).
16. Switch circuit breaker to ON position. Monitor for normal operation.
1
4
2
3
0066 00-2