TM 5-6350-255-13
Table 5-1. TROUBLESHOOTING - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
d
If paraph c fails, check code plug setting for proper parity (Table 5-2) and receiver for correct bit rate
setting and repeat pargraph c
e
If paragraph d. fails., test the battery using the GCeneral Automaticl Test Equipment (GATE) as follow.
Check the battery voltage for +28 +/-3 volts acros pins G (+) and B (-) of the interface connector. When
the voltage is out of tolerance, replace the battery and repeat paragraph c
f.
Replace defective battery as follows.
WARNING
Do not short out battery terminals. Shorted mercury battery may explode, causing injury
to personnel, and damage to equipment.
(1) Depress safety spring and met power switch to OFF position (fig. 5-2)
(2) Remove battery cap asembly (fig. 5-4) with a counterclockwie movement to disengage the bayonet
lock.
Figure 5-4. Installation of battery cap (Models AN/GSQ-154 (V) and AN/GSQ-154A (V)).
5-5