TM 9-4940-556-14&P
1
DESCRIPTION
NOMENCLATURE
1.1
The
RI 2400 is a skid mounted Combination Steam Cleaner and heated
or cold Pressure Washer capable of heating 200 GPH to 350F lOF in the
STEAM MODE and 300 GPH at 400 psi to 180F lOF in the PRESSURE MODE.
The unit will operate in the. PRESSURE MODE to produce 240 GPH - 400 psi
spray at ambient water temperature. The RI 2400 can operate with or
without cleaning compound.
PURPOSE AND FUNCTION
1.2
Unit is designed for cleaning of equipment. It will remove dirt, grease,
oil and will decontaminate. Unit can be used with or without cleaning
compound.
DIMENSIONS, WEIGHT, VOLUME, CENTER OF GRAVITY
1.3
LENGTH : 49.5 in 55.5 with liftfng/tie-down eyes
Width:
36.5 in 38.5 with hose and gun rack
HEIGHT: 55.5
HEIGHT:
1200 lbs. with gun, hoses, rack, cover - dry.
CENTER OF GRAVITY: See drawing number JP7223.
POWER AND WATER REQUIREMENTS
1.4
230 V., 1 ph
VOLTAGE:
50/60 Hz.
11 and Fuse 15 amp Slow Blow
CURRENT:
4 GPM @ 25 to 125 psi or un-pressurized water source
WATER:
with an elevation no greater than 10 feet lower than unit.
ENVIRONMENTAL REQUIREMENTS
1.5
Continous electrical spark and open flame present during operation.
DO NOT operate in combustible atomsphere or explosion will result.
1.5.1 Unit consumes oxygen during operation. Adequate fresh air must
be provided during operation.
1.5.2 If unit is operated inside a building it must be vented to the
outside. Open rain cap and install a 10 inch draft diverter and connect
to a 10 inch class A flue.
1.5.3 If unit is operating in a heated room and vented to the outside
during winter, a damper must be installed in flue and closed when unit
is not in operation to prevent coil from freezing.
1