TM 9-4940-556-14&P
PACKING LIST
1.6
1
RI 2400 Cleaner
Suction Supply Hose - 1 inch ID x 35 feet with foot valve and coupling
1
1
Steam Hose 25 ft. long with coupling
1
Steam Hose 50 ft. long with coupling
1
Cleaning Wand with squeeze shut-off valve
1
Steam Blast Nozzle with orifice
1
2.inch Flat Steam Nozzle
1
4 inch Flat Steam Nozzle
1
Pressure Washer Tip
Pulley for 50 Hz. operation
Instruction Manuals
1
Inlet Water Hose 50 ft. 3/4 inch ID
Pack Fuse Plugs
1
ITEMS REQUIRED FOR OPERATION
1.7
POWER SOURCE: 230 V., 50/60 Hz., 1 ph (Fuse 15 amp Slow Blow.)
PLUG: To match power receptacle
WATER SOURCE: 25 to 125 psi 6 GPM minimum
STORAGE
1.8
1.8.1 Drain solution tank. Add 1 gallon anti-freeze (NSN 6850-00-644-1430)
and 1 quart of water to solution tank.
1.8.2 Drain float tank using drain plug at bottom side of tank. Replace
drain plug.
1.8.3 Remove fuse plug after water has stopped draining from unit, re-
install fuse plug.
1.8.4 Fill float tank with anti-freeze mixture (75% NSN 6850-00-664-1430,
25% water) - approximately 3 gallons.
1.8.5 Connect unit to electric supply.
1.8.6 Place end of cleaning gun into float tank, open nozzle control
valve on gun, hold open. Turn main power ON, set MODE switch for steam,
turn pump ON. Before float tank empties add two additional gallons of
75% anti-freeze 25% water solution. This will permit anti-freeze/water
solution to re-circulate thru unit.
1.8.7 After five (5) minutes of operation, close gun control to allow
anti-freeze to flow thru the unloader by-pass line.
1.8.8 Open solution control valve wide to permit anti-freeze solution
to flow thru solution lines and solution check valve.
2