TM 10-4510-207-14
(14) Replace any defective, missing, or damaged components.
(15) Send removed supply pump (9) to direct support maintenance for repair.
d. Installation.
(1) Be sure any defective, missing, or damaged components have been replaced.
(2) Install supply pump (9) and align mounting holes. Secure using four flat washers (25), bolts (24), flat
washers (23), and new self-locking nuts (22).
(3) Apply sealing compound to threaded ends of nipple (21) then install nipple and cross fitting (13). Be sure
cross fitting is installed as illustrated.
(4) Apply sealing compound to threaded ends of nipple (20) then install nipple and pressure switch (5). Be
sure pressure switch is upright when installing.
(5) Apply sealing compound to threaded end of coupling (1) then install coupling.
(6) Apply sealing compound to threaded end (s) of bushing (19), nipples (18), and coupling (11) then install
bushing, nipple, coupling (17), and coupling (11).
(7) Apply sealing compound to threaded end (s) of coupling (2), bushing (14), and nipple (16) then install
nipple, strainer (15), bushing and coupling.
(8) Install cold line hose assembly onto cross fitting (13). See paragraph 4.12.
(9) Install plug (12) and secure coupling (11).
(10) Install two conduit connectors (10) then install conduit, with wire leads inside, into conduit connectors.
(11) Connect wire leads to pressure switch (5) and supply pump (9) using tags and electrical schematic
(12) Install gasket (8), cover (7), and four screws (6).
(13) Install cover (4), and secure nut (3).
(14) Connect mating hose end coupling to coupling (2) and secure coupling.
(15) Connect mating hose end coupling to coupling (1) and secure coupling.
4-31