TM 10-4510-208-13&P
0039 00
REPLACE
Replace the Plumbing
WARNING
Repair of plumbing requires the use of tools in restricted spaces. Slipping wrenches can
cause serious injury.
CAUTION
Always use two pipe wrenches when tightening or loosening pipe fittings. Use one pipe
wrench to turn the fitting, and another to secure the pipe. Failure to do so can twist the
fitting on the pipe, damaging both.
NOTE
Ensure all water is drained from sink stand plumbing before proceeding. To drain the
shave stands, ensure the water supply to the shower is shut OFF. Disconnect the hoses
from the shave stand, and open the faucet.
1. Remove the quick disconnect hoses from both sides of the shave stand (1). Locate the quick
disconnect fittings (2).
2. Use a pipe wrench to remove the quick-disconnect fittings (2) from the hot and cold water lines (3)
and the drain pipe (4).
3. Apply anti-seize tape to the threads and connect new fittings (2) to water lines (3) and drain pipe (4).
1
3
2
4
0039 00-5