TM 10-4510-208-13&P
DIRECT SUPPORT MAINTENANCE
CONTAINERIZED SHOWER
SHOWER, ENCLOSED UNIT, SYSTEM
PLUMBING
REPAIR, REPLACE
INITIAL SETUP
Personnel Required
Tools
One
Shop Equipment Automotive Maintenance and Repair:
Organizational Maintenance, Common No. 1 (Item 4, WP 0048 00)
Equipment Condition
Containerized Shower / Shower,
Materials/Parts
Enclosed Unit, System set up.
Shut down water supply and
drain system. Main power and
circuit breaker No. 2/4/6 set to
the OFF position (Containerized
Shower only).
REPAIR
Repair Leaks to External Service Panel
WARNING
Repair of plumbing requires the use of tools in restricted spaces. Slipping wrenches can
cause serious injury.
1. Shut down water supply to the shower and drain system.
WARNING
Close the breaker panel door before proceeding. Striking the breaker panel door while
performing this maintenance task can produce serious head injuries.
2. Disconnect all water hoses.
3. Using a basin wrench, tighten a leaking -inch cold water supply QDC fitting (1), a 1-inch hot water
supply QDC fitting (2), or a 2-inch drain fitting (3).
4. If leakage continues, replace the leaking component.
0044 00-1