C 2, SB 740-94-8
b. Classification of defects for end item. Refer to
table H-2.
NOTE
Inspection of the launching cup and attached parts requires the removal of the launching cup
from the launcher. Refer to TM 9-1010-224-10 for disassembly and reassembly instructions.
Table H-2. Launcher, Projectile, 64 Millimeter: Riot Control, M234, NSN 1010-01-014-6506
Defect
Categories Numbers
Defects
Inspection Method
Critical:
None defined
Major:
101
Component missing (refer to TM 9-11010-224-10).
Visual
102
Launcher body cracked or dented.
Visual
103
Front or rear sight cracked, broken, or bent.
Visual
104
Retaining pin broken or bent.
Visual
105
Launcher cup cracked, dented, or corroded.
Visual
106
Launcher cup keys missing, cracked, or broken.
Visual
107
Buffer cracked, distorted, or deteriorated.
Visual
108
Manifold cracked, broken, or distorted.
Visual
109
Retaining plate cracked, broken, or distorted.
Visual
Other
Visual
Minor:
Other
Visual
Change 2 H-2