Table 6-3. Hardware for Bolt and Nut Bonding or Grounding to Flat Surface
ELECTRONIC EQUIPMENT SHOCK MOUNT BONDING PRESERVATION

Cleaning and Corrosion Control Volume III - Aviation and Electronics
Page Navigation
  81    82    83    84    85  86  87    88    89    90    91  
img
. . . . . . . . . . .
NAVAIR 01-1A-509-3
01 March 2005
TM 1-1500-344-23-3
TO 1-1-689-3
Alcohol, Isopropyl
6
TT-I-735
e. Wipe clean with a cloth, Non-Woven Wiping
Cloth, A-A-162 Type I Class 1 or 2 (Volume IV or V,
Chapter 2), dampened with Isopropyl Alcohol, TT-I-735
(Volume IV or V, Chapter 2).
f. Allow to air dry.
g. If structure is magnesium or aluminum, treat the
bare metal surface with Chemical Conversion Material
Figure 6-11. Copper Jumper Connector to
in accordance with Chapter 5.
Tubular Structure
h. Clean bonding cable with a cloth, Non-Woven
Wiping Cloth, A-A-162 Type I Class 1 or 2 (Volume IV
or V, Chapter 2), dampened with Isopropyl Alcohol,
TT-I-735 (Volume IV or V, Chapter 2).
i. If necessary, use a Brush, A-A-3077 (Volume IV
or V, Chapter 3), to scrub the strap until all corrosion
products and contaminants are dislodged.
j. Wipe clean with the solvent-dampened cloth
and allow to air dry.
k. A s s e m b l e connection(s) and torque in
accordance with the requirements of the applicable
service directives.
l. Test electrical resistance in accordance with
Figure 6-12. Bonding Conduit to Structure
paragraph 6-3.1.12.
Figure 6-13. Aluminum Jumper Connector to
Tubular Structure
6-41