TM 10-3510-208-12
TS 10-3510-208-12/4-2
Figure 4-2, Positioning strainer in water source.
f. Connect the water heater exhaust duct (12,
i. Connect the washer-extractor drain hose (14)
fig. 4-1 ) to
the water heater exhaust port.
to the drain pipe. Locate the other end of the hose
g. Connect the power cable (13) to the water
in water, downstream from the water pump suction
pump power receptacle and to the pump service
hose.
outlet.
j. Remove the step from the storage bin and
h. Connect the tumbler air exhaust duct to
the
install it.
tumbler air exhaust port. If possible, use scrap
k. Release the float holddown rod.
lumber or other suitable materiel to raise and
l. Remove the holddown bars.
support the ducts free from the ground. Be sure
the exhaust from the tumbler is vented to open air
and never inside a tent.
Section Il. MOVEMENT TO A NEW WORKSITE
4-3. Dismantling for Movement
e. Secure the water pump to the deck of the
a. Secure the float holddown rod.
trailer.
f. Install the holddown and tiedowns.
b. Remove the step and stow it in the storage
bin.
CAUTION
c. Remove all hoses, lines, and ducts and stow
To prevent the washer-extractor tiedown
them securely.
mounting bolts from vibrating loose during
d. Remove the suction line strainer and stow it
towing, it is essential that an additional
in the tool box.
lock-nut 3/4" x 10 UNC. NSN
4-3